Instructions for using the Koreli water air conditioning controller
Many people have installed water air conditioners /water-cooled air conditioners but don’t know how to use them. In fact, water air conditioners are very simple. Below, the editor will introduce to you the functional description of the Keruilai water air conditioner operator.
Button description
1. On/off button: After the power is turned on, the temperature display is normal. Press this button to turn on the refrigeration function (default is refrigeration mode), the circulating water pump and fan are turned on at the same time, and refrigeration operates normally.
2. Mode button: You can press this button to select cooling mode or air supply mode (independent fan operation) when it is not started. You can also press this button to select the mode after starting.
3. Swing leaf button: After the fan is started, press this button to turn on or off the swing leaf. After the water air conditioner is turned off, the swing leaf function is turned off.
4. Water inlet button: Press this button to manually open or close the water inlet solenoid valve.
5. Cleaning button: When the fan is turned off, press this button to open or close the drain valve. After the water-cooled air conditioner is turned on, the drain is forced to close.
show description
1. After the power is turned on, the indoor temperature and operating mode are displayed (default is cooling).
2. The flashing water droplets indicate that the circulating water pump is running.
3. The fan blades indicate that the water air conditioner is running.
4. The swing leaf and the icon show that the swing leaf is running.
5. Water inflow and the icon display indicate that the water inlet solenoid valve is open.
6. The drainage icon shows that the drainage valve is open.
7. The phase loss protection display indicates that there is a phase loss at the fan relay output or the power supply. At this time, the fan relay is forcibly disconnected. After eliminating the power failure, press the switch button again, the phase loss protection display disappears, and the fan relay output is normal.
8. Water shortage protection display (sensor connection is valid), indicating that the water level in the water-cooled air conditioner is too low! The low water level is detected continuously for 12 seconds. At this time, the circulation pump is forcibly disconnected, and the water shortage protection display lights up! After troubleshooting, restart the cooling mode , the circulation pump is running normally, and the water shortage protection display disappears!
Recommended related content:
Which places are water-cooled air conditioners mainly suitable for?
The higher the outside temperature, the better the cooling effect of the water air conditioner!
Source Statement:This article is originally edited or compiled by Guangdong Symphony Keruilai Air Coolers Co., Ltd.,Ltd. If reprinted, please indicate that it comes from Guangdong Symphony Keruilai Air Coolers Co., Ltd.。The above content (including images and text) is sourced from the internet. If there is any infringement, please contact our website promptly(400 168 3989)。