Installation precautions for industrial air conditioning
As the quality of industrial air conditioners continues to improve, the environmental requirements are not particularly obvious. Keruilai industrial air conditioners can also be used well in some harsh environments. However, if the installation of industrial environmentally friendly air conditioners is not in place, the later use effects will be greatly reduced, and even the service life of industrial air conditioners will be directly reduced. So, what do you need to pay attention to when installing industrial environmentally friendly air conditioners?
1. Determine the number of industrial air conditioners in advance: Theoretically speaking, normal environments require an air exchange rate of 25-30 times/h, while public places with dense crowds require an air exchange rate of 30-40 times/h. As for production with heating equipment The workshop requires that the air exchange volume should be at least 40-50 times/h. We can calculate the actual required air volume through the formula "Volume of the room required to be cooled × Designed air exchange rate/Actual air volume of a single selected environmentally friendly air conditioner" Number of industrial air conditioners.
2. Reasonably choose the location of the industrial air conditioner: When selecting the installation location, be sure that its frame structure can support the entire main body of the air conditioner, the air supply duct, and the overall weight of the maintenance personnel. During installation, attention should be paid to sealing and waterproofing the pipes between the indoor and outdoor areas to avoid rainwater leakage. Moreover, in theory, it is best to install environmentally friendly air conditioners in the middle of the building to minimize the air supply resistance of the air duct and shorten the length of the installation duct; if possible, install the environmentally friendly air conditioner in the dominant wind direction of the cooling environment as much as possible.
3. Things to note when installing industrial air conditioners
(1) The material of the air supply duct is generally galvanized sheet, but plastic air duct, fiberglass, etc. can also be used.
(2) The specifications of the air supply duct are generally designed using the assumed flow velocity method. The main air duct is maintained at 8-10m/s, the branch air duct is 6-8m/s, and the end air duct is maintained at 4-6m/s.
(3) The air supply outlet of the environmentally friendly air conditioner is set in the place where cooling is actually required. The design air volume of the air outlet is the air supply volume required for the place to be cooled. The air outlet specifications can be determined based on the air volume and the air outlet wind speed. The air outlet material can be aluminum alloy. Or plastic and other products.
Source Statement:This article is originally edited or compiled by Guangdong Symphony Keruilai Air Coolers Co., Ltd.,Ltd. If reprinted, please indicate that it comes from Guangdong Symphony Keruilai Air Coolers Co., Ltd.。The above content (including images and text) is sourced from the internet. If there is any infringement, please contact our website promptly(400 168 3989)。