About Keruilai

About Keruilai

Keruilai was founded in the year 2001, and over the course of the last 22 years, the company has consistently strived for excellence. As a result of its unwavering dedication, Keruilai has become a well-known global organization. It boasts advanced manufacturing facilities, a state-of-the-art research and development center, and a strong and effective sales network.

Learn more
Products

Products

Since its inception, Keruilai has dedicated its efforts to the advancement and manufacture of evaporative air coolers designed for industrial, commercial, and residential use, all under one roof. Presently, Keruilai offers comprehensive solutions to cater to various air cooling requirements, spanning from 300 cubic meters per hour (CMH) to an impressive 100,000 CMH airflow capacity. Keruilai's global presence extends to 50 countries and continues to expand steadily.

Learn more
Solutions or Applications

Solutions or Applications

Over the course of several years, Keruilai has assembled a remarkable team of professionals who possess extensive expertise and experience in various domains, including research and development, product management, sales, and marketing.

Learn more
Technical support

Technical support

Keruilai possesses state-of-the-art laboratories dedicated to enhancing the efficiency of large-scale evaporation, measuring air volume and pressure, and assessing noise levels.

Learn more
Events

Events

the evaporative cooling technology of Keruilai is also highly recognized by the industry. As the leader of the drafting group and the main drafting unit, Keruilai has participated in the formulation of a number of national industry standards for evaporative air conditioners and cooling fans. And obtained more than 50 patents for domestic inventions,utility model and appearance.

Learn more
Contact us

Contact us

Thanks to the exceptional teamwork, Keruilai received numerous prestigious accolades, including designations such as "Notable Trademarks of Guangdong Province," "Guangdong's Distinguished Brand Product," "High-Tech Enterprise," and "National AAAA Standardization Excellence in the Industry," among others.

Learn more
076922188788Ext.963
400 168 3989
Welcome message
Thank you for your attention. Please fill in your information and we will contact you as soon as possible.
Company events
News and events

Maintenance and upkeep rules for evaporative air conditioning units

Release time:2020-05-29
Reading volume:269

  The weather is very cold in winter, and generally Keruilai evaporative air-conditioning units will be stopped. Before the season is shut down, we need to strengthen the maintenance of the evaporative air-conditioning units . Please pay attention to the following details.

  First, remove the wet curtain:

  1. First unscrew the two screws on the upper part of the wet curtain.

  2. Hold the louver on the upper part of the wet curtain, gently pull the wet curtain outward and then lift it up slightly to remove the wet curtain.

  Second, remove the top cover and water distribution pipe assembly

  1. First unscrew the screws on the top cover, then lift the top cover up and take it off.

  2. Unscrew the hose clamp on the water pipe and loosen the water pipe. Lift up the water pipe assembly and take it off.

 

Evaporative air conditioner

 

  Third, cleaning of evaporative air conditioner water pipes

  1. First unscrew the screws on the water distribution pipe cover.

  2. Remove the water pipe cover and then the code.

  3. Unscrew the screws on the water distribution pipe and disassemble the water distribution pipe.

  Fourth: Cleaning of chassis and accessories

  1. Clean the chassis: You can use a soft cloth or brush to clean the chassis.

  2. Clean the fan blades: You can wipe the fan blades with a soft cloth. Be careful not to let dust on the fan blades fall into the air duct

  3. Clean the water level sensor: Use a small damp cloth to clean the stains on the water level.

  4. Clean the water pump: Use a brush to clean the stains on the water pump and filter.

  5. Clean the drain valve: Pay attention to the dirt on the bottom of the drain valve.

  Fifth: Cleaning of wet curtain

  1. When cleaning, pay attention to the water pressure not being too high. It is strictly forbidden to use acidic or alkaline detergents to clean the wet curtain. The filter can be taken out and cleaned once a week.

  Sixth: After cleaning, reinstall the evaporative air conditioner in the reverse order of the disassembly steps.

  Keruilai Company is committed to the R&D and production of various ventilation and cooling equipment such as environmentally friendly air conditioners, water- cooled air conditioners, industrial air conditioners, evaporative air conditioners, evaporative cooling fans, industrial air coolers, and industrial large fans, and provides services such as factory cooling and outdoor cooling. Welcome to consult.

Source Statement:This article is originally edited or compiled by Guangdong Symphony Keruilai Air Coolers Co., Ltd.,Ltd. If reprinted, please indicate that it comes from Guangdong Symphony Keruilai Air Coolers Co., Ltd.。The above content (including images and text) is sourced from the internet. If there is any infringement, please contact our website promptly(400 168 3989)。